EMC Abstracts

Official abstracts site for the European Microscopy Congress

MENU 
  • Home
  • Meetings Archive
    • The 16th European Microscopy Congress 2016
  • Keyword Index
  • Your Favorites
    • Favorites
    • Login
    • Register
    • View and Print All Favorites
    • Clear all your favorites
  • Advanced Search

Time-resolved cathodoluminescence in a scanning electron microscope

Abstract number: 6725

Session Code: IM03-263

DOI: 10.1002/9783527808465.EMC2016.6725

Meeting: The 16th European Microscopy Congress 2016

Session: Instrumentation and Methods

Topic: New Instrumentation

Presentation Form: Poster

Corresponding Email: smeuret@amolf.nl

Sophie Meuret (1), Hans Zeijlemaker (1), Elke Neu (2), Patrick Appel (2), Patrick Maletinsky (2), Albert Polman (1)

1. AMOLF, FOM, Amsterdam, Pays-Bas 2. Department of Physics, University of Basel, Basel, Suisse

Keywords: Nano-optics, Time-resolved Cathodoluminescence

The past decade has witnessed enormous progress in the design and fabrication of nanostructured materials with unique optical properties. These tiny physical structures allow geometrical control over the electromagnetic shape of light well below its own wavelength. A large variety of applications for this field of subwavelength optics known as nanophotonics have already begun to emerge, including solar photovoltaics, chemical sensing, quantum cryptography, and LED lighting. Many fundamental optical interactions are hidden beneath the diffraction limit, however, which makes the retrieval of subwavelength optical behavior impossible with standard microscopy. An alternative approach, known as cathodoluminescence (CL) [1], is to probe nanostructures with an electron beam, which excites optical resonances and transitions and then collects the emitted light. It has recently been used to characterize plasmonic structure [2] or III-N heterostructures [3]. Thanks to a very efficient CL system, in a scanning electron microscope (SEM), working in free space, we can directly probed many key dimensions of light – including intensity, angle, polarization, and frequency – with ~10 nm resolution [4].

In this presentation we will show how we can use a blanker to modulate a continuous electron beam to generate electron pulses with a resolution of ~10 ns. This approach has several advantages compared to alternatives such as a laser driven pulsed electron gun [5]. It can be easily implemented in any SEM, it requires few experimental modifications, it does not require a dedicated microscope and the pulsed electron beam can be controlled at will (pulse duration and repetition rate). We will show how this pulsed electron gun can be used to explore the dynamics of a single photon emitter, such as a rare earth ion or the NV0 center of nano-diamond. An HBT interferometer allows recording of the autocorrelation function of the CL signal [6][7]. Combining secondary electron images with measurements of the CL spectra, emission polarizations, lifetimes and second order correlation function, we are able to fully characterize optically active systems at the nanometer scale.

 

[1] L. H. Robins, L. P. Cook, E. N. Farabaugh and A. Feldman. PRB 39 13367 (1989)

[2] E.J.R. Vesseur and A. Polman, Nano Lett. 11, 5524 (2011)

[3] L.F Zagonel et al, Nano Lett. 11, 568 (2011)

[4] C. Osorio, T. Coenen, B.J.M. Brenny, A. Polman, and A.F. Koenderink, ACS Photon. 3, 147 (2016)

[5] D-S. Yang, O. F. Mohammed and A. H. Zewail, PNAS 107, 14993 (2010)

[6] Mark Fox. Quantum Optics: An Introduction. Oxford Master Series in Physics, (2006).

[7] L. H. G. Tizei and M. Kociak, PRL 110  153604 (2013)

To cite this abstract:

Sophie Meuret, Hans Zeijlemaker, Elke Neu, Patrick Appel, Patrick Maletinsky, Albert Polman; Time-resolved cathodoluminescence in a scanning electron microscope. The 16th European Microscopy Congress, Lyon, France. https://emc-proceedings.com/abstract/time-resolved-cathodoluminescence-in-a-scanning-electron-microscope/. Accessed: September 21, 2023
  • Tweet
  • Email
  • Print
Save to PDF

« Back to The 16th European Microscopy Congress 2016

EMC Abstracts - https://emc-proceedings.com/abstract/time-resolved-cathodoluminescence-in-a-scanning-electron-microscope/

Most Viewed Abstracts

  • mScarlet, a novel high quantum yield (71%) monomeric red fluorescent protein with enhanced properties for FRET- and super resolution microscopy
  • 3D structure and chemical composition reconstructed simultaneously from HAADF-STEM images and EDS-STEM maps
  • Layer specific optical band gap measurement at nanoscale in MoS2 and ReS2 van der Waals compounds by high resolution electron energy loss spectroscopy
  • Pixelated STEM detectors: opportunities and challenges
  • Developments in unconventional dark field TEM for characterising nanocatalyst systems

Your Favorites

You can save and print a list of your favorite abstracts by clicking the “Favorite” button at the bottom of any abstract. View your favorites »

Visit Our Partner Sites

The 16th European Microscopy Congress

The official web site of the 16th European Microscopy Congress.

European Microscopy Society

European Microscopy Society logoThe European Microscopy Society (EMS) is committed to promoting the use and the quality of advanced microscopy in all its aspects in Europe.

International Federation of Societies for Microscopy

International Federation of Societies for Microscopy logoThe IFSM aims to contribute to the advancement of microscopy in all its aspects.

Société Française des Microscopies

Société Française des MicroscopiesThe Sfµ is a multidisciplinary society which aims to improve and spread the knowledge about Microscopy.

Connect with us

Imaging & Microscopy
Official Media Partner of the European Microscopy Society.

  • Help & Support
  • About Us
  • Cookie Preferences
  • Cookies & Privacy
  • Wiley Job Network
  • Terms & Conditions
  • Advertisers & Agents
Copyright © 2023 John Wiley & Sons, Inc. All Rights Reserved.
Wiley