Performance of the SALVE III corrector for EFTEM applications

Abstract number:

Session Code:

Meeting: The 16th European Microscopy Congress 2016

Session: Instrumentation and Methods

Topic: Spectromicroscopies and analytical microscopy (electrons and photons, experiment and theory)

Presentation Form: Oral Presentation

Corresponding Email:

Frank Kahl (1), Martin Linck (1), Peter Hartel (1), Heiko Mueller (1), Stephan Uhlemann (1), Max Haider (1), Joachim Zach (1)

1. Research & Development, CEOS GmbH, Heidelberg, Allemagne

Keywords: aberration-correction, Cc-corrector, EFTEM, Low voltage, SALVE

The Sub-Angstroem-Low-Voltage-Electron-Microscope (SALVE) corrector was designed and built by the CEOS GmbH for the SALVE III project [1], a joined project of the group of Prof. Dr. Ute Kaiser at the University of Ulm (Germany), FEI company in Eindhoven (Netherlands) and CEOS GmbH (Germany). This Cc-Cs-corrector is a dedicated low-voltage corrector based on the so-called Rose-Kuhn-Design [2], operated in a cubed FEI Titan Themis TEM for acceleration voltages from 20kV to 80kV. For all these high tensions it can be aligned such that it provides uniform phase contrast transfer for all image features up to an aperture angle of θmax = 50mrad and at the same time for a considerable field of view.

 

To achieve such an excellent performance the corrector allows correcting all axial aberrations of fourth order and for certain unround axial aberrations of fifth order. Furthermore, C5 can be adjusted to its optimum positive value for bright atom contrast. All axial aberrations up to third order and all off-axial aberrations up to third order depending linearly on the distance from the axis can be adjusted. For all residual axial aberrations of fourth and fifth order, the lower order aberrations of same respective multiplicity can be adjusted for optimal compensation. This means that the integrated squared deviation from the ideal phase shift (±π/2 in case of C1, C3, C5 and zero for all other multiplicities) over the entire aperture is minimized for each azimuthal multiplicity separately [3]. The predicted performance of the corrector has already been demonstrated for the five acceleration voltages 20kV, 30kV, 40kV, 60kV and 80kV [4]. Figure 1 (a) shows that even within the largest field of view reasonable with the mounted Ceta 4k camera the wave aberration hardly changes up to a scattering angle of 50mrad.

 

Since the corrector will also be used together with a post column energy filter, we currently investigate both, theoretically and experimentally, how the optical performance of an EFTEM image is affected by the corrector. After correction of the linear chromatic aberration Cc, an energy window of at least 20eV can be transferred by the corrector with a negligible focus change even at a beam energy of 20keV, see figure 1 (b). However, there are many more potentially harmful types of chromatic aberrations to consider for an EFTEM image of a given finite width of the energy window:

 

   • Axial chromatic aberrations (depending on scattering angle and energy loss)

      can deteriorate the quality of the axial PCTF. For large EFTEM windows

      also the chromatic spherical aberration has to be taken into account.

   • Off-axial chromatic aberrations (depending on scattering angle, distance from the axis and energy loss)

      can effectively decrease the field of view, because they affect the quality of the transfer function

      in the outer image parts.

   • Chromatic distortions (depending on distance from the axis and energy loss)

      can deteriorate the information limit in the outer regions of an EFTEM image.

   • Residual dispersions of higher order in energy change could affect

      the information limit of all regions of the EFTEM image.

 

In this work we will analyze in detail how the residual higher order chromatic aberrations, the remaining chromatic distortions and the residual dispersions of the SALVE corrector affect the EFTEM performance. [5]

 

References:


Figures:

Figure 1: (a) The phase plate of all axial aberrations for the 20kV alignment as measured in [4] is shown at the center. In the outer areas of the CCD additional phase shift contributions are generated by the off-axial aberrations of second and third order also measured in [4]. Within the 50mrad aperture marked by the red circles their contributions are so small that they barely alter the phase plate. For the mounted Ceta 4k camera oversampling the Nyquist limit of the smallest image point 1/g_max = λ/50mrad by a factor of three results in a field of view of 965 image points in diagonal. (b) Energy dependency of the defocus C1 at 20kV.

To cite this abstract:

Frank Kahl, Martin Linck, Peter Hartel, Heiko Mueller, Stephan Uhlemann, Max Haider, Joachim Zach; Performance of the SALVE III corrector for EFTEM applications. The 16th European Microscopy Congress, Lyon, France. https://emc-proceedings.com/abstract/performance-of-the-salve-iii-corrector-for-eftem-applications/. Accessed: December 2, 2023
Save to PDF

« Back to The 16th European Microscopy Congress 2016

EMC Abstracts - https://emc-proceedings.com/abstract/performance-of-the-salve-iii-corrector-for-eftem-applications/

Most Viewed Abstracts

  • mScarlet, a novel high quantum yield (71%) monomeric red fluorescent protein with enhanced properties for FRET- and super resolution microscopy
  • 3D structure and chemical composition reconstructed simultaneously from HAADF-STEM images and EDS-STEM maps
  • Layer specific optical band gap measurement at nanoscale in MoS2 and ReS2 van der Waals compounds by high resolution electron energy loss spectroscopy
  • Pixelated STEM detectors: opportunities and challenges
  • Developments in unconventional dark field TEM for characterising nanocatalyst systems

Your Favorites

You can save and print a list of your favorite abstracts by clicking the “Favorite” button at the bottom of any abstract. View your favorites »

Visit Our Partner Sites

The 16th European Microscopy Congress

The official web site of the 16th European Microscopy Congress.

European Microscopy Society

European Microscopy Society logoThe European Microscopy Society (EMS) is committed to promoting the use and the quality of advanced microscopy in all its aspects in Europe.

International Federation of Societies for Microscopy

International Federation of Societies for Microscopy logoThe IFSM aims to contribute to the advancement of microscopy in all its aspects.

Société Française des Microscopies

Société Française des MicroscopiesThe Sfµ is a multidisciplinary society which aims to improve and spread the knowledge about Microscopy.

Imaging & Microscopy
Official Media Partner of the European Microscopy Society.

  • Help & Support
  • About Us
  • Cookie Preferences
  • Cookies & Privacy
  • Wiley Job Network
  • Terms & Conditions
  • Advertisers & Agents
Copyright © 2023 John Wiley & Sons, Inc. All Rights Reserved.
Wiley