Optimizing electron channeling contrast imaging condition in scanning electron microscope

Abstract number: 6188

Session Code: IM03-225

DOI: 10.1002/9783527808465.EMC2016.6188

Meeting: The 16th European Microscopy Congress 2016

Session: Instrumentation and Methods

Topic: New Instrumentation

Presentation Form: Poster

Corresponding Email: luyang.han@zeiss.com

Luyang Han (1), Bjoern Gamm (1)

1. Carl Zeiss Microscopy GmbH, Oberkochen, Allemagne

Keywords: channeling contrast, electron channeling pattern, quantification

The electron channeling contrast imaging (ECCI) is a technique that makes use of the influence of back scattered electrons (BSE) by the relative orientation of crystalline lattice and incident electron beam [1]. The ECCI in scanning electron microscope (SEM) is especially useful to image the crystallographic defects such as dislocations, stacking faults and twin boundaries [2]. In this contribution the amount of channeling contrast in the total BSE signal is quantified and its dependence on different working conditions is explored.

An example of the ECCI on an epitaxial GaN thin film is shown in Figure 1. The sample is investigated using ZEISS GeminiSEM 500 FE-SEM with a PIN-diode BSE detector under the objective lens. By adjusting the strength of the scanning coil it is possible to move the pivot point of scanning electron down to the surface of the sample, forming the selected area channeling pattern (SACP) [1]. The intensity variation of BSE signal can be extracted by the line profile across the Kikuchi line, shown as the red dotted line in the figure. The relative variation of BSE signal in SACP with respect to average signal can thus be used as a quantification of channeling contrast.

The amount of channeling contrast is influenced by the properties of incident electron beam and the detector. In principle, the energy and convergence angle of the incident electron beam determines the channeling pattern itself, while the position and energy response of the detector influence the amount of channeling contrast. In this study a large parameter space is explored to optimize the channeling contrast, including electron beam energy, working distance, convergence angle and position of detectors. As an example, the influence of electron beam energy to channeling contrast is summarized in Figure 2. The SACPs are shown in the right part of the figure. The position of the lines as well as intensity variations within the pattern changes significantly between different energies. However, quantification of the channeling contrast shows a clear trend of increasing channeling contrast at lower electron beam energy.

Reference:

[1] L. Reimer, Scanning Electron Microscopy, 2nd. Edition (Springer) 359

[2] I. Gutierrez-Urrutia, et. al., Scripta Materialia 61 (2009) 737

Figures:

Figure 1: ECCI of dislocations in GaN thin film (left) and corresponding SACP (middle). The center of SACP (red dot) indicates the relative orientation of electron beam in ECCI with respect to the crystalline lattice. A line profile along the red dotted lines shows the BSE intensity variation with electron beam rocking angle (right). The relative change of the signal is quantified as the channeling contrast.

Figure 2: SACPs of GaN thin film with different electron beam energy are shown in the left part. The channeling contrast is quantified in the right plot.

To cite this abstract:

Luyang Han, Bjoern Gamm; Optimizing electron channeling contrast imaging condition in scanning electron microscope. The 16th European Microscopy Congress, Lyon, France. https://emc-proceedings.com/abstract/optimizing-electron-channeling-contrast-imaging-condition-in-scanning-electron-microscope/. Accessed: September 25, 2023
  • Tweet
  • Email
  • Print
Save to PDF

« Back to The 16th European Microscopy Congress 2016

EMC Abstracts - https://emc-proceedings.com/abstract/optimizing-electron-channeling-contrast-imaging-condition-in-scanning-electron-microscope/

Most Viewed Abstracts

  • mScarlet, a novel high quantum yield (71%) monomeric red fluorescent protein with enhanced properties for FRET- and super resolution microscopy
  • 3D structure and chemical composition reconstructed simultaneously from HAADF-STEM images and EDS-STEM maps
  • Layer specific optical band gap measurement at nanoscale in MoS2 and ReS2 van der Waals compounds by high resolution electron energy loss spectroscopy
  • Pixelated STEM detectors: opportunities and challenges
  • Developments in unconventional dark field TEM for characterising nanocatalyst systems

Your Favorites

You can save and print a list of your favorite abstracts by clicking the “Favorite” button at the bottom of any abstract. View your favorites »

Visit Our Partner Sites

The 16th European Microscopy Congress

The official web site of the 16th European Microscopy Congress.

European Microscopy Society

European Microscopy Society logoThe European Microscopy Society (EMS) is committed to promoting the use and the quality of advanced microscopy in all its aspects in Europe.

International Federation of Societies for Microscopy

International Federation of Societies for Microscopy logoThe IFSM aims to contribute to the advancement of microscopy in all its aspects.

Société Française des Microscopies

Société Française des MicroscopiesThe Sfµ is a multidisciplinary society which aims to improve and spread the knowledge about Microscopy.

Connect with us

Imaging & Microscopy
Official Media Partner of the European Microscopy Society.

  • Help & Support
  • About Us
  • Cookie Preferences
  • Cookies & Privacy
  • Wiley Job Network
  • Terms & Conditions
  • Advertisers & Agents
Copyright © 2023 John Wiley & Sons, Inc. All Rights Reserved.
Wiley