Multicomponent garnet film scintillators for SEM electron detectors

Abstract number: 5236

Session Code: IM03-232

DOI: 10.1002/9783527808465.EMC2016.5236

Meeting: The 16th European Microscopy Congress 2016

Session: Instrumentation and Methods

Topic: New Instrumentation

Presentation Form: Poster

Corresponding Email: petr@isibrno.cz

Petr Schauer (1), Ondřej Lalinský (1), Zuzana Lučeničová (2), Miroslav Kučera (2)

1. Department of Electron Microscopy, Institute of Scientific Instruments of the CAS, Brno, République tchèque 2. Faculty of Mathematics and Physics, Charles University, Prague, République tchèque

Keywords: Electron detector, Epitaxial film, GAGG:Ce, Multicomponent garnet, Scintillator, SEM

With an Everhart-Thornley (ET) scintillation detector in SEM, an image is formed by signal electrons emerged after an interaction of focused scanning electron beam with the specimen surface. In such a case a scintillator plays an important role as a fast electron-photon signal conversion element. A selection of fast scintillation materials is very limited, because the only mechanism for scintillators applicable in SEM ET detectors consists in allowed 5d-4f transitions in lanthanide ions. Unfortunately, the widely used Czochralski grown single crystal YAG:Ce scintillators suffer from an afterglow, which deteriorate the ability to transfer high image contrast. The mentioned afterglow in the bulk single crystal is caused by inevitable structural defects, such as antisite defects. These trap states are responsible not only for delayed radiative recombination causing the afterglow, but also for a degradation of the light yield. The aim of this study is to introduce new multicomponent garnet film scintillators for SEM electron detectors that due to the substitution of Al by Ga in the Gd3Al5O12:Ce garnet extensively supress the shallow traps resulting in a significant increase of the cathodoluminescence (CL) efficiency and in improvement of the afterglow characteristics.

To avoid the defective bulk scintillators, isothermal dipping liquid phase epitaxy was chosen as a method for garnet single crystalline film preparation [1]. The high purity Ce activated GAGG (Gd3Al1.7Ga3.3O12:Ce) film of the thickness of 11 µm, grown on the single crystal YGG (Y3Ga5O12) substrate, was chosen to assess its applicability as the scintillator in the scintillation detector in SEM. Results of Monte Carlo (MC) simulation of electron interaction [2] in the GAGG:Ce film as well as in the YAG:Ce bulk scintillator in different depth of the scintillator are shown in Fig. 1. It is evident from the MC simulation that electron interaction active layers of the garnet scintillators are much thinner than 10 µm for standard signal electron energy. Furthermore, it is seen that the GAGG:Ce scintillators may be even thinner than the YAG:Ce ones. Comparison of optical absorption coefficients of the GAGG:Ce film,  YAG:Ce crystal and YGG substrate is in Fig. 2, and CL emission spectra of these scintillators obtained using the apparatus for the cathodoluminescence study [3] are shown in Fig. 3. The optical self-absorption together with the refractive index and the emission spectra of the scintillators are very important quantities for an assessment of the signal photon transport in the both examined scintillators. Although the GAGG:Ce film exhibits higher optical absorption, it has a higher collection efficiency of signal photons, since the path of photons in this film is much shorter than the path of photons in the bulk YAG:Ce scintillator, which was verified by MC simulation of a light transport [4] in the scintillation detector for SEM. As seen in Fig. 3, the CL efficiency of both scintillators is approximately the same. However, the GAGG:Ce film do not suffer from parasitic UV host emission. Regarding the scintillator-PMT matching, for both scintillators the photocathode S20 should be used. CL decay characteristics of both examined scintillators, measured using the CL apparatus [3], are shown in Fig. 4. The decay time as low as 22 ns and the afterglow of only 0.043 % at 0.5 µs after the end of excitation predetermines the GAGG:Ce film scintillators for extremely fast and efficient electron detectors in SEMs.

Acknowledgement
The research was supported by Czech Science Foundation (GA16-05631S and GA16-15569S), by Technology Agency of the Czech Republic (TE01020118), by Ministry of Education, Youth and Sports of the Czech Republic (LO1212), and by European Commission and Ministry of Education, Youth and Sports of the Czech Republic (CZ.1.05/2.1.00/01.0017).

References

[1] Bok, J.; Lalinský, O.; Hanuš, M.; Onderišinová, Z.; Kelar, J.; Kučera, M.: GAGG:Ce single crystalline films: New perspective scintillators for electron detection in SEM, Ultramicroscopy 163 (2016), 1‑5.

[2] Schauer, P.; Bok, J.: Study of spatial resolution of YAG:Ce cathodoluminescent imaging screens, Nucl. Instr. Meth. B 308 (2013), 68‑73.

[3] Bok, J.; Schauer, P.: LabVIEW-based control and data acquisition system for cathodoluminescence experiments, Rev. Sci. Instrum. 82 (2011), 113109.

[4] Schauer, P. Extended Algorithm for Simulation of Light Transport in Single Crystal Scintillation Detectors for S(T)EM, Scanning, 29 (2007), 249-253.

Figures:

Fig. 1. Monte Carlo simulation of electron absorbed energy distribution in GAGG:Ce and YAG:Ce scintillators for different primary electron beam.

Fig. 2 Optical absorption spectra of GAGG:Ce film scintillator, YAG:Ce single crystal scintillator and of YGG single crystal substrate.

Fig. 3 Cathodoluminescence emission spectra of GAGG:Ce film and YAG:Ce single crystal scintillators together with sensitivities of standard PMT photocathodes.

Fig. 4 Cathodoluminescence decay characteristics of GAGG:Ce film scintillator and YAG:Ce single crystal scintillator.

To cite this abstract:

Petr Schauer, Ondřej Lalinský, Zuzana Lučeničová, Miroslav Kučera; Multicomponent garnet film scintillators for SEM electron detectors. The 16th European Microscopy Congress, Lyon, France. https://emc-proceedings.com/abstract/multicomponent-garnet-film-scintillators-for-sem-electron-detectors/. Accessed: September 21, 2023
  • Tweet
  • Email
  • Print
Save to PDF

« Back to The 16th European Microscopy Congress 2016

EMC Abstracts - https://emc-proceedings.com/abstract/multicomponent-garnet-film-scintillators-for-sem-electron-detectors/

Most Viewed Abstracts

  • mScarlet, a novel high quantum yield (71%) monomeric red fluorescent protein with enhanced properties for FRET- and super resolution microscopy
  • 3D structure and chemical composition reconstructed simultaneously from HAADF-STEM images and EDS-STEM maps
  • Layer specific optical band gap measurement at nanoscale in MoS2 and ReS2 van der Waals compounds by high resolution electron energy loss spectroscopy
  • Pixelated STEM detectors: opportunities and challenges
  • Developments in unconventional dark field TEM for characterising nanocatalyst systems

Your Favorites

You can save and print a list of your favorite abstracts by clicking the “Favorite” button at the bottom of any abstract. View your favorites »

Visit Our Partner Sites

The 16th European Microscopy Congress

The official web site of the 16th European Microscopy Congress.

European Microscopy Society

European Microscopy Society logoThe European Microscopy Society (EMS) is committed to promoting the use and the quality of advanced microscopy in all its aspects in Europe.

International Federation of Societies for Microscopy

International Federation of Societies for Microscopy logoThe IFSM aims to contribute to the advancement of microscopy in all its aspects.

Société Française des Microscopies

Société Française des MicroscopiesThe Sfµ is a multidisciplinary society which aims to improve and spread the knowledge about Microscopy.

Connect with us

Imaging & Microscopy
Official Media Partner of the European Microscopy Society.

  • Help & Support
  • About Us
  • Cookie Preferences
  • Cookies & Privacy
  • Wiley Job Network
  • Terms & Conditions
  • Advertisers & Agents
Copyright © 2023 John Wiley & Sons, Inc. All Rights Reserved.
Wiley